“A compliant steriliser must provide clean water at the correct temperature every time.”
Immersion sterilisers protect against cross-contamination only while their water stays at or above the critical 82°C threshold and is clean. A shift away from continuous flow, made to save water and energy, results in a problematic cycle of temperature drops and contamination.
If the water is below 82 °C, the steriliser cannot be compliant
Where it fails, and how the Econoliser fixes it
-
1The problem
Continuous flow
Keeps the steriliser clean and at temperature — but this uses as much as 3 litres per minute, per steriliser.
3 L / minHigh water useEconoliser solutionTimed spray, not constant flow
140mL dispensed each time a knife is sterilised, water usage now linked to kill rate, no kill no water used.
0.14 L / cycle≈90% less water -
2The problem
Refresh left to the operative
Relying on the operative to decide when to refresh the water does not satisfy the HACCP regulations.
Non-compliantEconoliser solutionNo standing water to refresh
Placing a knife or tool in the Econoliser triggers the spray automatically, so operatives don’t have to manage refresh.
Full complianceAutomated spray -
3The problem
Feed water below temperature
Refreshing with water at less than 82 °C risks reducing the temperature of the water in the steriliser to below 82 °C — restoring the temperature takes time, while the steriliser is below 82 °C it is non-compliant.
Non-compliantEconoliser solutionHeats its own water
The Econoliser’s built-in water heater maintains the water temperature at 90 °C even when using cold inlet water — it is always compliant.
Always above 82 °CNo central 90 °C supply -
4The problem
Low-cost thermostats
A thermostat is used to control the heating element, however the temperature they switch on at can be 10–12 °C below the point they switch off at — so the water in the steriliser can be well below 82 °C before the heating element switches on.
Non-compliantEconoliser solutionMicroprocessor-controlled heat
A microprocessor and two temperature sensors hold a constant supply of 90 °C water, so it never drifts below the line.
Always at temperatureAlways compliant -
5The problem
Dirty standing water
When the water in the tank isn’t refreshed often enough, the water becomes more and more contaminated and on withdrawal from the steriliser the knife is re-contaminated.
ContaminationEconoliser solutionFlushed every cycle
Dirty water is expelled after every sterilisation cycle, and there’s no standing water left to become contaminated.
Zero build-upNo cross-contamination -
6The problem
Steam and condensation
Immersion sterilisers produce steam all day long, leading to contaminated condensation forming on surfaces and causing non-compliance.
ContaminationEconoliser solutionReduced steam = less condensation
The design and short spray duration of the Econoliser means that they produce virtually no steam, reducing the chance of contaminated condensation dripping onto carcases.
Virtually no steamLess condensation